PRODUCTS
IBP transducer cables and adapter cables that carry a clean, accurate pressure signal from transducer to monitor — because the accuracy of an invasive pressure reading depends on the cable as much as the transducer.
Made in our own ISO 13485 factory with biocompatible materials, low-noise shielded cable and 100% electrical testing on every unit. Custom lengths and connector combinations through OEM/ODM.

Invasive blood pressure monitoring leaves no room for signal error: the waveform on the monitor drives immediate clinical decisions. Our IBP cables use low-noise shielded cabling and precision-molded connectors to deliver the transducer signal without distortion or interruption.
We manufacture single and dual-pressure IBP cables, plus adapter cables that connect popular disposable transducer sets to different monitor platforms — a small accessory that saves ICU equipment budgets significantly.
SIGNAL YOU CAN TRUST
Shielded cable construction preserves the accuracy of the pressure waveform from transducer to monitor.
Cables and adapters for the major disposable pressure transducer brands used in ICUs worldwide.
Supports arterial and CVP / dual-channel monitoring configurations.
Medical-grade strain reliefs withstand the constant handling and repositioning of critical care.
| Product | Channels | Standard Length | Application |
|---|---|---|---|
| IBP transducer cable | Single | 6 ft / 12 ft | Arterial pressure monitoring |
| Dual-pressure IBP cable | Dual | 6 ft / 12 ft | ART + CVP simultaneous monitoring |
| Transducer adapter cable | Single | 6 ft | Connects branded transducer sets to monitors |
| Custom IBP assembly | 1–2 | Custom | Device OEM integration |
We manufacture cables and adapters for the major disposable transducer brands used with leading monitors. Tell us your transducer and monitor models and we confirm the match within 1 working day.
In most cases yes. If the pinout is known or a sample is available, we can develop a compatible version through our OEM process in days, not months.
The cable is a passive link; calibration happens at the transducer and monitor. Our role is to deliver the signal without introducing noise or intermittent connections.
INSIDE MR.MEDICAL
90 seconds inside our Shenzhen plant — no third-party outsourcing, no anonymous sub-suppliers.
Muted autoplay loop — tap the video to unmute with sound.
For buyers who source through customs or bill-of-lading data — how these goods typically appear in trade records. HS codes are for sourcing reference only; final classification follows the rules of the destination country.
| Item | Reference |
|---|---|
| HS code (reference) | 9018.19 |
| Primary trade term | IBP cable |
| Also seen on bills of lading as | invasive blood pressure cable, pressure transducer cable, transducer interface cable |
| Customs-data sourcing fit | Good — searchable, but the term itself is narrow |
Send us the monitor brand and model, connector photos or drawings — quotation within 1 working day, samples in 3.